Before  Installation

During Installation

After  Installation Complete

PRODUCTS SPECIFICATION

1. MAJOR DIFFERENCES BETWEEN Connect Technologies AND STANDARDS

  • Standards provide performance requirements for the components and the link without specifying or identifying a matched system. Connect Technologies tests components and channels and can explain how the components will work together as a system.
  • Standards allow for impedance smoothing; Connect Technologies does not.
  • Connect Technologies's patch cord specs include both return loss and NEXT.
  • Connect Technologies won't accept splices or non-virgin materials.
  • Connect Technologies requires power sum testing for connecting hardware (as well as for cable and channel), while the standards do not.

 

TIA Cat 5
TIA-568A Oct-95 (
Obsolete)

TIA Cat 5E
TIA-568B May-01

TIA Cat 6 Draft 8
May-01

ALC 6
R17.00L
Nov-00

ALC 7
R17.00L
Nov-00

Connect Technologies
R3.00XP
Nov-00

Connect Technologies
R3.00XP
Nov-00

Maximum Test Frequency

100 MHz

100 MHz

250 MHz

250 MHz

350 MHz

250 MHz

350 MHz

Passive Testing @ 100 MHz:

 

 

(db)

(db)

(db)

(db)

(db)

(db)

(db)

Attenuation (The lower the number, the better solution)

 

Cable

22.0

22.0

19.8

22.0

19.8

21.7

19.7

Connector

0.4

0.4

0.2

0.4

0.2

0.4

0.2

Channel

24.0

24.0

21.3

24.0

20.8

23.8

20.9

Power Sum NEXT (The higher the number, the better solution)

 

Cable

N/A

32.3

42.3

34.3

43.3

34.3

44.3

Connector

N/A

N/A

50.0

41.0

50.0

41.0

50.0

Channel

N/A

27.1

37.1

28.6

37.6

28.6

37.6

Power Sum ACR (The higher the number, the better solution)

 

Cable

N/A

N/A

22.5

12.3

23.5

12.6

23.6

Channel

N/A

N/A

15.8

4.6

16.8

4.9

16.8

Power Sum ELFEXT (The higher the number, the better solution)

 

Cable

N/A

20.8

24.8

23.8

25.8

23.8

25.8

Connector

N/A

N/A

40.1

34.0

40.1

34.0

40.1

Channel

N/A

14.4

20.3

16.8

20.8

16.8

20.8

Return Loss (The higher the number, the better solution)

 

Cable

15.0

20.1

20.1

20.1

20.1

21.5

22.5

Connector

14.0

20.0

24.0

20.0

24.0

21.0

24.0

Channel

N/A

10.0

12.0

10.0

12.0

12.0

14.0

 2. QUICK OVERVIEW: COMPARE XP LEVELS TO THE OTHERS

 

TIA/EIA Cat 5E

Other Programs

Connect Technologies

Tested for:

 

Attenuation

V

V

V

NEXT

V

V

V

Power Sum ACR

V

V

V

Return Loss

 

 

V

Purchasing Specification

 

 

V

All Manufacturers Must Meet ISO 9001

 

 

V

Inventory Not Compliant Is Sent Back To Manufacturer

 

 

V

Cable Cannot Have Any Splices

 

 

V

Exceeds:

 

ANSI/ICEA 5-90-661

 

 

V

CSA

 

 

V

UL 444

 

 

V

ANSI/TIA/EIA 568-A

 

 

V

ISO/IEC 11801

 

 

V

CENELEC EN50173: 1995

 

 

V

NEC NFPA70

 

 

V

NEMA NFPA 70

 

 

V

NEMA WC-63/66

 

 

V

Use Only Virgin Materials

 

 

V

Testing Components Since 1988

 

 

V

Component Tested

 

 

V

Channel Tested

 

 

V

Tested & Tuned to Work Together

 

 

V

Patch Cords Tested

 

 

V

Input Impedence Measured Per ASTM 4566-94, 43.2 Method 2, Option 2

 

 

V