PRODUCTS
SPECIFICATION
1. MAJOR
DIFFERENCES BETWEEN Connect Technologies AND STANDARDS
-
Standards provide performance
requirements for the components and
the link without specifying or
identifying a matched system. Connect Technologies
tests components and channels and
can explain how the components will
work together as a system.
-
Standards allow for impedance
smoothing; Connect Technologies does not.
-
Connect Technologies's
patch cord specs include both return
loss and NEXT.
-
Connect Technologies
won't accept splices or non-virgin
materials.
-
Connect Technologies
requires power sum testing for
connecting hardware (as well as for
cable and channel), while the
standards do not.
|
|
TIA Cat 5
TIA-568A Oct-95 (Obsolete)
|
TIA Cat 5E
TIA-568B May-01
|
TIA Cat 6
Draft 8
May-01
|
ALC 6
R17.00L
Nov-00
|
ALC 7
R17.00L
Nov-00
|
Connect Technologies
R3.00XP
Nov-00
|
Connect Technologies
R3.00XP
Nov-00
|
|
Maximum Test
Frequency
|
100 MHz
|
100 MHz
|
250 MHz
|
250 MHz
|
350 MHz
|
250 MHz
|
350 MHz
|
|
Passive
Testing @ 100 MHz:
|
|
|
|
(db)
|
(db)
|
(db)
|
(db)
|
(db)
|
(db)
|
(db)
|
|
Attenuation
(The lower the number, the
better solution)
|
|
|
Cable
|
22.0
|
22.0
|
19.8
|
22.0
|
19.8
|
21.7
|
19.7
|
|
Connector
|
0.4
|
0.4
|
0.2
|
0.4
|
0.2
|
0.4
|
0.2
|
|
Channel
|
24.0
|
24.0
|
21.3
|
24.0
|
20.8
|
23.8
|
20.9
|
|
Power Sum
NEXT (The higher the number, the
better solution)
|
|
|
Cable
|
N/A
|
32.3
|
42.3
|
34.3
|
43.3
|
34.3
|
44.3
|
|
Connector
|
N/A
|
N/A
|
50.0
|
41.0
|
50.0
|
41.0
|
50.0
|
|
Channel
|
N/A
|
27.1
|
37.1
|
28.6
|
37.6
|
28.6
|
37.6
|
|
Power Sum ACR
(The higher the number, the
better solution)
|
|
|
Cable
|
N/A
|
N/A
|
22.5
|
12.3
|
23.5
|
12.6
|
23.6
|
|
Channel
|
N/A
|
N/A
|
15.8
|
4.6
|
16.8
|
4.9
|
16.8
|
|
Power Sum
ELFEXT (The higher the number,
the better solution)
|
|
|
Cable
|
N/A
|
20.8
|
24.8
|
23.8
|
25.8
|
23.8
|
25.8
|
|
Connector
|
N/A
|
N/A
|
40.1
|
34.0
|
40.1
|
34.0
|
40.1
|
|
Channel
|
N/A
|
14.4
|
20.3
|
16.8
|
20.8
|
16.8
|
20.8
|
|
Return Loss
(The higher the number, the
better solution)
|
|
|
Cable
|
15.0
|
20.1
|
20.1
|
20.1
|
20.1
|
21.5
|
22.5
|
|
Connector
|
14.0
|
20.0
|
24.0
|
20.0
|
24.0
|
21.0
|
24.0
|
|
Channel
|
N/A
|
10.0
|
12.0
|
10.0
|
12.0
|
12.0
|
14.0
|
2.
QUICK OVERVIEW: COMPARE XP LEVELS TO THE
OTHERS
|
|
TIA/EIA Cat
5E
|
Other Programs
|
Connect Technologies
|
|
Tested for:
|
|
|
Attenuation
|
V
|
V
|
V
|
|
NEXT
|
V
|
V
|
V
|
|
Power Sum ACR
|
V
|
V
|
V
|
|
Return Loss
|
|
|
V
|
|
Purchasing Specification
|
|
|
V
|
|
All Manufacturers Must Meet ISO
9001
|
|
|
V
|
|
Inventory Not Compliant Is Sent
Back To Manufacturer
|
|
|
V
|
|
Cable Cannot Have Any Splices
|
|
|
V
|
|
Exceeds:
|
|
|
ANSI/ICEA
5-90-661
|
|
|
V
|
|
CSA
|
|
|
V
|
|
UL
444
|
|
|
V
|
|
ANSI/TIA/EIA 568-A
|
|
|
V
|
|
ISO/IEC 11801
|
|
|
V
|
|
CENELEC EN50173: 1995
|
|
|
V
|
|
NEC NFPA70
|
|
|
V
|
|
NEMA NFPA 70
|
|
|
V
|
|
NEMA WC-63/66
|
|
|
V
|
|
Use Only Virgin Materials
|
|
|
V
|
|
Testing Components Since 1988
|
|
|
V
|
|
Component Tested
|
|
|
V
|
|
Channel Tested
|
|
|
V
|
|
Tested & Tuned to Work Together
|
|
|
V
|
|
Patch Cords Tested
|
|
|
V
|
|
Input Impedence Measured Per
ASTM 4566-94, 43.2 Method 2,
Option 2
|
|
|
V
|
|